1800 425 6594
ProductTitle: ORION SERIES
Product Category : UPS Systems
Product Sub Category :3:3 ONLINE UPS
● Online double-conversion with full DSP control
● IGBT inverter with output isolation transformer
● 100% unbalance load capability
● Output power factor 0.8
● Generator compatible
● Support battery cold start and auto-restart when mains power is restored
● Superior protection
● Intelligent self-diagnosing function, all kinds of failure protection
● Standard emergency power off (EPO)
● Standard RS232,RS485,dry contacts communication port
● Optional SNMP communication port
● Optional N+X redundancy parallel up to 6 units
● Optional input filter to improve input power factor
MODEL |
EA8910 |
EA8915 |
EA8920 |
EA8930 |
EA8940 |
EA8960 |
EA8980 |
EA89100 |
EA89120 |
Capacity |
10 KVA |
15 KVA |
20 KVA |
30 KVA |
40 KVA |
60 KVA |
80 KVA |
100 KVA |
120 KVA 108 KW |
INPUT |
|||||||||
Rated voltage |
380 V / 400 V / 415 Vac |
||||||||
Voltage range |
± 25% |
||||||||
Rated frequency |
50 / 60 Hz |
||||||||
Frequency range |
50 / 60 Hz ± 5 Hz |
||||||||
Power factor |
≥ 0.95 (with filter) |
||||||||
Bypass voltage range |
± 20%(settable) |
||||||||
Delayed start of rectifier |
1 ~ 300 s (settable via display panel) |
||||||||
ECO voltage range |
± 10% (settable) |
||||||||
OUTPUT |
|||||||||
Voltage |
380 V / 400 V / 415 Vac |
||||||||
Voltage regulation |
±1% |
||||||||
Frequency |
Synchronized with utility in mains mode; 50 / 60 Hz ± 0.1% in battery mode |
||||||||
Waveform |
Sinusoidal |
||||||||
Power factor |
0.9 |
||||||||
Crest factor |
3:1 |
||||||||
Total harmonic distortion(THDV) |
≤ 2%(linear load); ≤ 5% (non-linear load) |
||||||||
Transfer time |
AC mode to battery mode: 0 ms |
||||||||
Inverter overload capability |
105%: long time running; |
||||||||
Slight adjustment of inverter output voltage |
± 5 V |
||||||||
BATTERIES |
|||||||||
DC Voltage |
12 V ×configured battery number (settable via display panel) |
||||||||
Number of battery |
28 ~ 32 pcs (settable) |
||||||||
Charging current |
10 A default / Settable |
||||||||
Charging |
Three-stage charging, auto switch floating / equalizing charge |
||||||||
Battery state display |
Display battery backup time, battery remaining capacity |
||||||||
Battery self-test |
Settable periodic self-test; manually configurable test time and voltage |
||||||||
SYSTEM |
|||||||||
Efficiency |
In line mode: Max. 93%; ECO mode: ≥ 98% |
||||||||
Max. Parallel numbers |
6 |
||||||||
Protections |
Short-circuit – overload – overvoltage – undervoltage – low battery – overtemperature – fan fault |
||||||||
IP rating |
IP20 |
||||||||
EMI |
EN62040-2 |
||||||||
EMS |
IEC61000-4-2 (ESD) |
||||||||
IEC61000-4-3 (RS) |
|||||||||
IEC61000-4-4 (EFT) |
|||||||||
IEC61000-4-5 (surge) |
|||||||||
COMMUNICATIONS |
|||||||||
RS232 / RS485 / dry contacts (standard) |
Supports Windows 98 / 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10 |
||||||||
SNMP (optional) |
Power management from SNMP manager and web browser |