1800 425 6594

PRODUCT DETAILS

CHLORIS LITE

ProductTitle: CHLORIS LITE
Product Category :Solar Power Products
Product Sub Category :Solar Inverter

 CHLORIS LITE
Built for high performance against the typically tough Indian grid conditions,CHLORIS LITE Series provides you an economical power solution and gives the benefit of optimal renewable energy, 365 days a year.Advanced DSP control technology and high efficiency MPPT gives you the maximum solar generation and a true sinewave so that even your sensitive appliances can run uninterrupted for a long time.
  • Combined with solar power controller and inverter hybrid function.

  • DSP Controlled Design is used.

  • Pure sine wave output with inbuilt isolation.

  • User friendly display gives status of the system.

  • Intelligent  automatic bypass  & charging ( On utility mode)

  • Surge, over voltage, lightening protection.

  • Overload ,Short circuit, Deep discharge protection

  • MNRE approval (Under Processing)



MODEL

500W

1000W

2000W

2500W

3000W

Rated power

500 W

1000 W

2000 W

2500 W

3000W

Battery voltage

12 Vdc

24/48 Vdc

48 Vdc

PV INPUT

Max. input voltage (Voc)

60 Vdc

100 Vdc

150 Vdc

Optimum operating voltage (Vmp)

16 ~ 48 Vdc

33 ~ 80 Vdc

65 ~ 120 Vdc

Max. charging current

50 A

50 A

50 A

65 A

65 A

Recommended PV configuration

700 W

1400 W

2800 W

3500 W

3500 W

AC INPUT

AC input range (bypass mode)

0 ~ 132 Vac / 0 ~ 264 Vac (high-end limit)

Rated input voltage

100 Vac / 110 Vac / 115 Vac / 120 Vac or 200 Vac / 220 Vac / 230 Vac / 240 Vac ± 25%
(2500W only for 110Vac; 3000W only for 220Vac)

Rated Input frequency

50 Hz / 60 Hz ± 5 Hz (auto-sense)

Max. charging current

20 A

30 A

INVERTER OUTPUT

Output voltage

100 Vac / 110 Vac / 115 Vac /120 Vac ± 2% or 200 Vac / 220 Vac / 230 Vac / 240 Vac ± 2% (settable)
(2500W only for 110Vac; 3000W only for 220Vac)

Rated output power

500 W

1000 W

2000 W

2500 W

3000 W

Power factor

1

Rated output frequency

50 Hz / 60 Hz ± 1%

Waveform

Sinusoidal

Max. efficiency (resistive load)

≥ 78%

≥ 82%

≥ 85%

≥ 85%

≥ 85%

Sleep mode

Settable (< 3% load) access in ≤ 2 min

Output voltage harmonic

≤ 3% (linear load)

BATTERIES

Charging current

5 ~ 50 A (settable)

5 ~ 65 A (settable)

DOD

9.6 ~ 13.0 Vdc / cell (settable), 10.8 Vdc / cell (default)

EOD

9.6 ~ 11.5 Vdc / cell (settable), 10.2 Vdc / cell (default)

Equalizing charge voltage

13.6 ~ 15.0 Vdc / cell (settable), 14.1 Vdc / cell (default)

Floating charge voltage

13.2 ~ 14.6 Vdc / cell (settable), 13.5 Vdc / cell (default)

Restroration point of overvoltage

15.5 Vdc

31.0 Vdc

62.0 Vdc